20-Slot 200kW Whatsminer 2U Integrated Hydro Cooling Rack

Designed for Whatsminer hydro miners, this hydro cooling cabinet supports 20 M53, M63, or M73 units as an integrated all-in-one cooling and deployment solution with a 200kW cooling capacity.

    💬

    Customize Your Hydro Cooling Solution

    Share your requirements below. Our consultant will contact you via email, WhatsApp, or call within 24 hours with a custom setup and quote.

    Immediate4–8 weeks8–12 weeks12+ weeks

    Price range: $11,820.00 through $12,800.00

    Not Fitting Your Site?

    Tell us your mining capacity and site requirements, and we'll recommend the right hydro-cooling container for your deployment.

      💬

      Customize Your Hydro Cooling Solution

      Share your requirements below. Our consultant will contact you via email, WhatsApp, or call within 24 hours with a custom setup and quote.

      How your container order works

      1

      Submit form

      Tell us delivery country & site details

      2

      Get your quote

      Complete pricing within 24 hours

      3

      Expert review

      Discuss specs, customise setup

      4

      DDP delivery

      Container shipped to your site

      Industrial-scale farms deploying 200+ hydro-cooled ASICs.

      CONTAINER CAPACITY

      ASIC MINERS

      20 UNITS

      Housed at full load

      TOTAL POWER

      200 KW

      Continuous electrical load

      FORM FACTOR

      Custom

      Standard

      COOLING

      Hydro

      Thermal management

      POWER INPUT

      380V–415V AC 50/60Hz

      AVAILABILITY

      Typical lead time 15 days • DDP Sea Shipping Available

      Product Description

      Designed for professional WhatsMiner 2U hydro mining deployments, this 20-slot 200kW integrated hydro cooling rack combines miner installation, liquid cooling, and heat management into one complete solution.

      The all-in-one cabinet design simplifies deployment by integrating key cooling components into a compact structure, reducing installation complexity and improving space utilization. With a plug-and-play design, users can quickly connect power and complete basic setup for efficient mining operation. The dedicated liquid circulation system and optimized thermal management provide stable cooling performance for continuous workloads.

      Suitable for home mining, warehouses, and indoor deployment environments with available space, this integrated hydro cooling rack offers a compact and efficient solution for operators seeking a convenient way to deploy multiple ASIC miners with minimal installation requirements.

      Core Advantages

      bitcoin miner cooling cabinet

      01. Specialized 2U Slots & Manifolds

      The rack features 20 dedicated 2U slots with a specialized manifold system. Every miner has its own water connection points, ensuring a perfect fit and even liquid distribution for stable cooling during hashing daily.

      28-Slot 154kW Antminer Water Cooling Cabinet power supply

      02. Organized Power Cabinet Wiring

      The power cabinet features neatly organized wiring and utilizes UL-compliant components to meet safety standards. This clean layout simplifies troubleshooting and ensures long-term fire safety for your facility now.

      ASIC hydro cooling system

      03. Independent Switch for Each Slot

      Every slot has its own power switch and breaker. This one-miner, one-control design allows you to turn off a single machine for maintenance without stopping the rest of the rack, maximizing your overall mining uptime now.

      cryptocurrency mining cabinet

      04. Reliable Leak Detection Safety

      A moisture-sensing rope is installed at the bottom to detect any coolant leaks. If fluid is found, the system triggers an instant alert, protecting your hardware from water damage and keeping your facility safe daily now.

      28-Slot 154kW Antminer Water Cooling Cabinet CDU

      05. Complete CDU System Function

      The CDU includes a heavy-duty pump, expansion tank, and heat exchanger. It maintains stable pressure and circulation, moving the 200kW heat load from the miners to the outside radiator for continuous thermal balance now.

      28-Slot 154kW Antminer Water Cooling Cabinet with PLC Controller

      06. Customizable PLC Control Hub

      The PLC system monitors data automatically and can be customized for your site needs. The clear HMI screen shows all real-time pressure and temperature, ensuring safe and efficient system operation at all times now.

      Full Specifications

      External dimensions

      L:1460mm、W:1000mm、H:2200mm

      Internal dimensions

      L:1410mm、W:950mm、H:2150mm

      Weight

      500KG

      Model

      AP-M20

      Installed capacity

      20 Seat

      Installed powerload

      200 kW

      Power of the light-duty vertical multistage pump

      4 kW

      Power of the fluid replenishing pump

      0.2 kW

      Total power of the dry cooling tower fan

      8.3 kW

      Total power of the closed cooling tower fan

      3 kW

      Total power of the closed cooling tower spray pump

      1.1 kW

      System pipeline pressure

      0.2-0.4 MPA

      Operating temperature range of the system

      0-50 ℃

      Coolant circulation demand of a single machine

      ≥0.6 m³/h

      Total demand for circulating coolant within the system

      ≥0.25 m³

      Residual Current Circuit Breaker

      400 A

      Contactor

      9 A

      Intermediate relay

      24 V

      CUL certified frequency converter

      380 V

      Plug & Play with Cooling system

      20-Slot Whatsminer Hydro Cooling Rack Product Brochure

      Complete product specifications, installation guide, and operational instructions.

        Data download verification

        Downloadable materials: 20-Slot 200kW Whatsminer 2U Integrated Hydro Cooling Rack

        Certification Standards

        Our products meet leading international standards for safety, reliability, and performance.

        China Classification Society

        Marine & offshore compliance

        UL Listed

        Safety tested & certified

        CSA Certified

        North American compliance

        CE Marking

        European conformity

        Complete Cooling Solutions

        We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

        ❄️ Cooling Capacity

        ⚙️ Miner Slots 

        📏 Dimensions (L × W × H)

        🏢 Application

        Whatminer Liquid Cooling Rack

        12-Slot Integrated Whatsminer Hydro Cooling Rack

        120 kW

        12 Slots

        8,50 × 1,000 × 2,130 mm

        Home & Professional Offices

        Compare

        WhatsMiner hydro cooling cabinet

        20-Slot Integrated Whatsminer Hydro Cooling Rack

        200 kW

        20 Slots

        1,460 × 1,000 × 2,200 mm

        Mid-Sized Mining Clusters

        WhatsMiner hydro cooling system

        160-Slot Whatsminer Hydro Cooling Container

        1.6 MW

        160 Slots

        6,058 × 2,438 × 2,896 mm

        Industrial Scale Facilities

        Whatminer 2.4MW 240 Slot hydro cooling container

        240-Slot Whatsminer Hydro Cooling Container

        2.4 MW

        240 Slots

        1,3716 × 2,438 × 2,896 mm

        Enterprise Mega Infrastructure

        20-Slot Whatsminer Integrated Hydro Cooling Rack FAQs

        Can this rack support 20 overclocked WhatsMiner Hydro miners?

        Yes. The rack is designed for high-power and overclocked WhatsMiner M53, M63, and M73 Hydro deployments, with up to 200kW of total miner load.

        WhatsMiner Hydro miners in these series can reach approximately 10kW per unit in high-performance operation, making this 200kW rack suitable for a fully populated 20-miner overclocking setup.

        Does the 200kW rating mean every miner slot is limited to 10kW?

        No. The 200kW rating refers to the total miner load of the complete rack, not a fixed 10kW limit for each individual position.

        This allows the rack to accommodate different compatible WhatsMiner models or operating modes, as long as the combined miner load remains within the system's 200kW design capacity.

        How does the system maintain enough coolant flow for all 20 miners?

        The rack provides a rated circulation flow of 13m³/h, with a minimum coolant circulation requirement of 0.6m³/h per miner.

        For 20 miners, the minimum combined requirement is approximately 12m³/h. The rack uses an automatic pressure-regulating pump and PLC constant-flow control to maintain stable circulation across the system.

        Will a problem with one miner affect the entire 20-miner rack?

        No. Each miner position is individually managed, so one miner can be taken offline for inspection or maintenance without treating the entire rack as a single operating unit.

        This design helps reduce unnecessary downtime and makes a 20-miner deployment easier to operate and service.

        What happens if coolant temperature, flow, pressure, or network conditions become abnormal?

        The rack uses PLC-based 24/7 monitoring to track key operating conditions including power, temperature, coolant flow, pressure, and network status.

        Abnormal conditions can be detected centrally, allowing operators to identify and respond to cooling or system issues before they develop into wider rack-level problems.

        How much on-site piping work is required during installation?

        The rack is supplied as an integrated cooling system with factory-prepared piping, valves, power components, and the required quick-connect interfaces.

        The corresponding quick connectors are prepared before shipment, allowing compatible WhatsMiner Hydro miners to connect directly to the rack's coolant supply and return lines and reducing additional field plumbing work.

        For a 200kW rack, should I use a dry cooler or a closed cooling tower?

        For most single-rack 200kW deployments, a matched 200kW dry cooler is a practical choice when simple installation, low water consumption, and lower routine water-system maintenance are priorities. The rack can also be configured with a closed cooling tower.

        For hotter climates or larger multi-rack sites where evaporative heat rejection provides an operational advantage, a closed cooling tower can be considered as part of the centralized cooling design. Dry coolers are generally preferred when water conservation and reduced maintenance are the main priorities.

        Can I expand from one 200kW rack to a 1MW mining deployment?

        Yes. The rack format is suitable for modular mining-farm expansion.

        Five 200kW racks represent approximately 1MW of installed miner capacity. If future expansion is planned from the beginning, the site can reserve sufficient electrical capacity, main piping, heat-rejection capacity, installation space, and centralized monitoring interfaces so additional racks can be added without rebuilding the entire infrastructure.