9-Slot 50kW Antminer Hydro Cooling Rack
The 9-unit 50kW Home Water Cooler is designed to cool up to 9 Antminer hydro miners, offering a space-saving and powerful cooling solution for medium-scale home mining setups.
$2,385.00 – $3,250.00Price range: $2,385.00 through $3,250.00
Not Fitting Your Site?
Tell us your mining capacity and site requirements, and we'll recommend the right hydro-cooling container for your deployment.
How your container order works
Submit form
Tell us delivery country & site details
Get your quote
Complete pricing within 24 hours
Expert review
Discuss specs, customise setup
DDP delivery
Container shipped to your site
Family mining deploying 9 hydro-cooled ASICs.
CONTAINER CAPACITY
9 UNITS
Housed at full load
50 KW
Continuous electrical load
Custom
Standard
Hydro
Thermal management
POWER INPUT
380V–415V AC 50/60Hz
AVAILABILITY
In stock, ready to ship • DDP Sea Shipping Available
View More ›





Show 1 more models
Product Description
As part of our home-use series, the water cooler includes both a hydro cooling cabinet and a dry cooling tower, offering an integrated solution for cooling up to 9 Antminer hydro miners. Its space-saving design ensures that it fits comfortably in home environments while offering high-efficiency cooling.
The closed-loop water cooling system uses deionized water to manage heat effectively, maintaining optimal operating temperatures for your mining rigs. The is the ideal choice for those looking to expand their home mining operations with a more robust cooling solution that still remains space-efficient.
Core Advantages

01. Integrated All-in-One System
The rack, CDU, power cabinet, and control unit are integrated into a single container for easy installation, quick deployment, and efficient mining operations with minimal setup.

02. Redundant Dual-Loop Cooling
Dual circulation loops, dual CDUs, and multi-channel power ensure single-side operation during power shortages, boosting energy efficiency and reliability for mining operations.

03. Individual Power Switches
Each miner is equipped with a labeled switch, allowing for easy maintenance on individual units without disrupting the overall mining system or operations.

04. Leak Detection System
Equipped with a moisture-sensing immersion rope, this system detects coolant leaks and triggers instant alarms, enhancing safety and preventing potential damage in liquid-cooled mining setups.

05. Excellence Roots in Details
Equipped with aviation plugs from Bitmain's supplier, reinforced grid panels for stable operation, and 304 stainless steel manifolds with ball valves and original connection pipes for durability.

06. Intelligent Management System
Multiple sensors monitor flow rate, pressure, temperature, and leakage, enabling real-time control, malfunction alerts, and quick intervention via mobile or PC for efficient mining operations.
Full Specifications
External dimensions
L:800mm、W:800mm、H:1600mm
Internal dimensions
L:750mm、W:750mm、H:1550mm
Weight
155KG
Model | AP-H9 | Installed capacity | 9 Seat |
Heat Dissipation Capacity | 50 kW | Circulation Mode | Single Mode / Dual Mode |
Coolant | Pure Water / Soft water + Antifreeze + Corrosion Inhibitor | Fluid Flow Rate | 4 m³/h |
Pump Head | 31 M | Speed | 2900r/min |
Input /Output Voltage | 3 Phase 380-415V 50/60Hz | Ambient Temp | -25°C ~ 45°C |
Cabinet Dimensions | 8,00mm(L) * 8,00mm(W) * 1,600mm(H) | Cabinet Weight | 155 KG |
Dry Cooler | |||
Total Capacuty | 50 kW | Allowance | 3-5% kW |
Exchange Surface | 1.28 ㎡ | Coil Internal Volume | 40± L |
Design Pressure | 0.3 MPa | Input/Output Voltage | 3 Phase 380-415V 50/60Hz |
Dry Cooler Dimensions | 1,100mm(L) * 1,100mm(W) * 1,400mm(H) | Dry Cooler Weight | 170 KG |
Antminer 9-POSITION-INTEGRATED-COOLING-SOLUTION
Complete product specifications, installation guide, and operational instructions.
Hydronic Heating Solution
Hydro cooling systems that double as flexible heating solutions—turning mining heat into efficient warmth anywhere it's needed.
Key Benefits & Applications:
- Versatile Heating Integration: Seamlessly supports underfloor heating, radiators, swimming pools, and other applications—offering efficient warmth across different environments.
- Customizable Options: Heating modules can be tailored to match your building layout, heating system, and specific usage requirements.
- Energy Reuse: Repurpose mining-generated heat to reduce energy waste and lower overall heating costs.

Complete Cooling Solutions
We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.
❄️ Cooling Capacity |
⚙️ Miner Slots |
📏 Dimensions (L × W × H) |
🏢 Application |
Compare

9-Slot 50kW
50 kW |
9 Slots |
8,00 × 8,00 × 1,600 mm |
Large-scale Mining Operations |
Real Results from Real Miners
View All >>

Large-scale mining
Deployed 20 liquid-cooled containers supporting the stable operation of 6,160 mining units
+28%
Efficiency Gain
-23%
Energy Cost
120W USD
Energy Cost
View All >>

Large-scale mining
Deployed 20 liquid-cooled containers supporting the stable operation of 6,160 mining units
+28%
Efficiency Gain
-23%
Energy Cost
120W USD
Energy Cost
View All >>
“
Amina’s liquid-cooled containers have enabled a quantum leap in energy efficiency and stability for our mining operations.
Director of Mining Operations
A major North American mining company
Amina’s liquid-cooled containers have enabled a quantum leap in energy efficiency and stability for our mining operations.
Director of Mining Operations
A major North American mining company
Amina’s liquid-cooled containers have enabled a quantum leap in energy efficiency and stability for our mining operations.
Director of Mining Operations
A major North American mining company
1.2+ GW
Cumulative delivered cooling capacity
50+
Countries and regions covered
FAQs
The standard input requires 380V - 415V Three-Phase Electricity. At full load (approx. 50kW), the rack draws around 72A to 76A per phase. You must prepare a dedicated circuit breaker of at least 100A to ensure safe operation without tripping.
You must use Deionized Water or high-purity distilled water for the internal loop. Never use tap water, as mineral mineral deposits (scale) will quickly clog the miner’s micro-channels and overheat the chips.
- Winter: If the ambient temperature drops below 0°C (32°F), you must blend the distilled water with specialized propylene glycol antifreeze (usually a 30% to 50% ratio depending on how cold it gets) to prevent the pipelines and dry cooler from cracking.
- Summer: The matching 50kW Dry Cooler is designed to dissipate full thermal heat up to 40°C (104°F) ambient temperature. If your local summer regularly exceeds 42°C, need an auxiliary water mist/spray kit to help cool down the dry cooler fins.
- Indoor Rack: Around 50 to 55 dB. It only houses the water pump and small control fans, producing a sound similar to a running household refrigerator.
- Outdoor Dry Cooler: Around 65 to 70 dB at 1 meter distance under full load. The noise comes from the large industrial cooling fans. It should be placed outdoors, away from your neighbor's bedroom windows.
The standard 9-slot rack has an approximate size of 800 x 1000 x 1600 mm. The net weight without miners is around 150 kg. It can fit through standard doorways and garage entrances easily.
The rack uses industrial-grade Quick-Disconnect (QD) fittings with internal valving. When you plug or unplug a miner for maintenance, the valves automatically snap shut on both sides, ensuring no coolant leaks onto the electrical components.