Liquid Cooling Cabinet For Whatsminer
12-Slot 120kW Whatsminer 2U Hydro Cooling Rack Price range: $9,350.00 through $10,350.00
Back to products
Best Antminer Home Water Cooler
12-Slot 70kW Antminer Hydro Cooling Rack Price range: $2,785.00 through $5,000.00

12-Slot 66kW Antminer Hydro Cooling Rack

The Antminer hydro cooling system is designed to support up to 12 units of Antminer S19, S21, and S23 Hydro miners with a 66kW cooling capacity.

    💬

    Customize Your Hydro Cooling Solution

    Share your requirements below. Our consultant will contact you via email, WhatsApp, or call within 24 hours with a custom setup and quote.

    Price range: $6,730.00 through $8,540.00

    Not Fitting Your Site?

    Tell us your mining capacity and site requirements, and we'll recommend the right hydro-cooling container for your deployment.

      💬

      Customize Your Hydro Cooling Solution

      Share your requirements below. Our consultant will contact you via email, WhatsApp, or call within 24 hours with a custom setup and quote.

      How your container order works

      1

      Submit form

      Tell us delivery country & site details

      2

      Get your quote

      Complete pricing within 24 hours

      3

      Expert review

      Discuss specs, customise setup

      4

      DDP delivery

      Container shipped to your site

      Optimized residential cooling for up to 12 hydro-cooled Antminers

      CONTAINER CAPACITY

      ASIC MINERS

      12 UNITS

      Housed at full load

      TOTAL POWER

      66 KW

      Continuous electrical load

      FORM FACTOR

      Custom

      Standard

      COOLING

      Hydro

      Thermal management

      POWER INPUT

      380V–415V AC 50/60Hz

      AVAILABILITY

      In stock, ready to ship • DDP Sea Shipping Available

      Product Description

      The 12-Slot 66kW Antminer Hydro Cooling Rack PLUS is built for miners who want the same compact 12-slot hydro cooling setup with a higher standard of hardware quality. It supports up to 12 Antminer hydro miners and brings cooling, miner mounting, power connections, and water lines together in one dedicated rack.

      The PLUS version places more emphasis on build quality and component selection, making it a better fit for users who prioritize solid construction and dependable long-term operation. The rack keeps the installation clean and accessible, with the cooling and power systems arranged around the miners for easier inspection and routine maintenance.

      For miners moving from a basic home setup toward a more organized operation, the PLUS provides a practical bridge between residential mining and professional rack deployment.

      Core Advantages

      liquid cooling for antminer mining

      01. Reinforced 12-Slot Rack Frame

      This 12-slot rack features a black-coated reinforced frame. It centralizes 12 Antminer hydro units in one place, providing an organized structure for cable and hose management in home or workshop environments.

      Hydro miner cooling solution Crypto MINING

      02. Industrial Stainless Steel Manifold

      The 304 stainless steel manifold is built for long-term durability. It features precision-welded pipes and manual shut-off valves for each slot, ensuring balanced coolant flow and reliable leak-free hashing.

      ANTMINER hydro cooling miners solution

      03. Organized Power Distribution Hub

      The power management section utilizes automatic reclosing breakers for enhanced safety. This individual switch layout provides over-current protection and allows maintenance on specific miners without total downtime.

      Hydro Cooling Suite Support Antminer

      04. Integrated CDU Circulation Module

      The integrated CDU module houses an industrial pump and a stainless steel expansion tank. It maintains stable fluid pressure and ensures the 66kW heat load is exported efficiently through the whole cooling loop.

      Hydro Cooled Rack For Bitcoin Mining

      05. Automated PLC Management System

      The intelligent PLC system monitors real-time fluid pressure, temperature, and flow rates. It features automated speed regulation for fans and pumps, ensuring the whole rack maintains a constant thermal balance safely.

      H12-PLUS dry cooler

      06. V-Type Corrosion-Resistant Cooler

      This V-type cooler uses a corrosion-resistant aluminum tube-fin structure. Its anti-clogging design ensures stable heat exchange in environments with impurities or corrosive media reliably for long-term mining operations.

      Full Specifications

      External dimensions

      L:900mm、W:1000mm、H:2000mm

      Internal dimensions

      L:850mm、W:950mm、H:1950mm

      Weight

      350KG

      Model

      AP-H12 Plus

      Installed capacity

      12 Seat

      Heat Dissipation Capacity

      66 kW

      Power of the light-duty vertical multistage pump

      2.2 kW

      Power of the fluid replenishing pump

      0.2 kW

      Total power of the dry cooling tower fan

      4.15 kW

      Total power of the closed cooling tower fan

      0.55 kW

      Total power of the closed cooling tower spray pump

      0.75 kW

      System pipeline pressure

      0.2-0.4 Map

      Operating temperature range of the system

      22-42 ℃

      Coolant circulation demand of a single machine

      ≥0.5 m³/h

      Total demand for circulating coolant within the system

      ≥0.12 m³

      Molded Case Circuit Breaker

      160 A

      Contactor

      9 A

      Intermediate relay

      160 V

      CUL certified frequency converter

      380 V

      Dry Cooler

      Cooling Capacity

      66 kW

      Fan Quantity

      1 Pcs

      Working Fluid

      Ethylene Glycol

      Fluid Flow Rate

      8.4 m³/h

      Inlet / Outlet Temperature

      48–40 ℃

      Ambient Temperature

      38 ℃

      Operating / Max Pressure

      0.25 / 0.4 MPa

      Dry Cooling Tower Fan Total Power

      8.3 kW

      Dry Cooler Dimensions

      1950*1920*1710 mm

      Dry Cooler Weight

      388 KG

      12-Slot Antminer Hydro Cooling Rack Product Brochure

      Complete product specifications, installation guide, and operational instructions.

        Data download verification

        Downloadable materials: 12-Slot 66kW Antminer Hydro Cooling Rack

        Hydronic Heat Recovery Solution

        Hydro cooling systems that double as flexible heating solutions—turning mining heat into efficient warmth anywhere it's needed.

        Key Benefits & Applications:

        • Versatile Heating Integration: Seamlessly supports underfloor heating, radiators, swimming pools, and other applications—offering efficient warmth across different environments.
        • Customizable Options: Heating modules can be tailored to match your building layout, heating system, and specific usage requirements.
        • Energy Reuse: Repurpose mining-generated heat to reduce energy waste and lower overall heating costs.
        H12 PLUS Hydronic Heating Solution

        Complete Cooling Solutions

        We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

        ❄️ Cooling Capacity

        ⚙️ Miner Slots 

        📏 Dimensions (L × W × H)

        🏢 Application

        Compare

        Antminer Water Cooler for Crypto Mining

        12-Slot Antminer Hydro Cooling Rack

        66 kW

        12 Slots

        9,00 × 10,00 × 2,000 mm

        Advanced Home Infrastructure

        AP-H9 Water Cooler

        9-Slot Antminer Hydro Cooling Rack

        50 kW

        9 Slots

        8,00 × 8,00 × 1,600 mm

        Professional Home Setups

        AP-H6 Hydro Cooling Solution

        6-Slot Antminer Hydro Cooling Rack

        35 kW

        6 Slots

        8,00 × 8,00 × 1,450 mm

        Standard Garage Operations

        AP-H4 liquid cooling system

        4-Slot Antminer Hydro Cooling Rack

        26 kW

        4 Slots

        1,070 × 7,00 × 1,390 mm

        Compact Entry-Level Mining

        12-Slot Home Hydro Cooling Rack FAQs

        Does 12 slots mean I can run any 12 Antminer Hydro miners?

        Not necessarily. The system provides 12 physical miner slots, but the actual number of miners that can operate simultaneously depends on their combined power consumption.

        The total miner load should remain within the system's 66kW capacity. For higher-power Hydro models, please confirm the total power consumption before deployment.

        How is coolant flow distributed across 12 miners?

        The system uses a centralized circulation loop and manifold to distribute coolant to each miner.

        Proper flow balancing is important in a multi-miner setup to ensure every miner receives sufficient coolant. The system has a rated circulation flow of 6m³/h, while individual miner flow requirements depend on the specific Antminer Hydro model.

        If one miner needs maintenance, do all 12 miners have to be shut down?

        No. Individual miner branches can be isolated for inspection or maintenance without shutting down the entire cooling system.

        This makes it easier to replace or service one miner while keeping the remaining miners in operation, reducing unnecessary downtime.

        Why is a dry cooler recommended for a 12-miner system?

        For a 12-miner deployment, a dry cooler offers a simpler and more cost-effective heat-rejection solution.

        Compared with a closed cooling tower, it requires less supporting equipment and is easier to install and maintain. Closed cooling towers are generally more suitable for larger centralized mining deployments.

        Can the system maintain cooling performance in hot weather?

        Cooling performance depends on total miner load, outdoor temperature, coolant temperature, airflow, and dry cooler operating conditions.

        The matched cooling system should be selected according to the site's maximum summer ambient temperature. For very hot regions, we recommend confirming the actual site conditions before finalizing the cooling configuration.

        How much additional power does the cooling system consume?

        The cooling system consumes additional electricity beyond the miners themselves.

        Power is required for the circulation pumps, control system, and dry cooler fans. These auxiliary loads should be included when calculating the total electrical capacity required for the complete 12-miner installation.

        How are all 12 miners monitored and managed?

        The system uses PLC-based intelligent control and supports MODBUS-RTU communication.

        Operating parameters such as system status, temperature, flow, and other cooling conditions can be monitored centrally, making it easier to manage a multi-miner Hydro installation and identify abnormal operating conditions.

        What coolant and routine maintenance are required?

        The system uses an ethylene-glycol-based cooling solution suitable for the installation environment.

        Routine maintenance includes checking coolant quality and level, system pressure, flow distribution, pumps, valves, hoses, pipe connections, leaks, and keeping the dry cooler clean with unobstructed airflow.