Overview of the Antminer L11 Serial Miners
As benchmark products in the Scrypt algorithm mining sector in 2025, the Bitmain Antminer L11 series has built a full-scenario mining solution through a graded lineup of standard, Pro, and water-cooled flagship models.
The entire Antminer L11 series adopts TSMC’s 3nm chip process. Compared with the 5nm process of the L9, the transistor density is increased by 30%, and the leakage rate is reduced by approximately 25%, directly leading to a 40% increase in hash rate per unit area. Aiming at the memory-intensive characteristics of the Scrypt algorithm, the high-bandwidth memory (HBM) interface and cache architecture are optimized, reducing data latency by 15%.
I. Detailed Explanation of Core Parameters for All Series Models
| Antminer L11 Hu6 | Antminer L11 | Antminer L11 Pro |
| Air&Hydro-Cooling in One | Air Cooling | Air Cooling |
| 33Gh | 20Gh | 21Gh |
| 5676W | 3680W | 3612W |
| 172J/G | 184J/G | 172J/G |
1.1 Standard Version Antminer L11
- Basic Specifications:
- Dimensions: 400×195×290mm (unpackaged), 570×316×430mm (packaged), compliant with 19-inch rack standards
- Weight: 14.5kg (net weight), 16.2kg (gross weight), slightly heavier than the previous-generation L9 miner (14.1kg)
- Interfaces: RJ45 Ethernet 10/100M, supporting remote firmware updates and hash rate monitoring
- Power Supply Requirements: Single-phase AC 220~277V, 50~60Hz, maximum input current 20A
- Core Performance Parameters:
- Hash Rate: Rated 20 GH/s, actual measured hash rate stably ranges from 18.5-19.2 GH/s (±3% fluctuation), supporting Scrypt-based coins such as LTC/DOGE/BEL
- Power Consumption: 3550-3720W (at 25℃ ambient temperature), approximately 5.6% higher than the L9 miner (3360W), but with a 15.6% increase in hash rate
- Power Efficiency Ratio: 185-193 J/GH, optimized by 12.8-11.9% compared to the L9 (210 J/GH). At an electricity price of
4.26-$4.46
- Heat Dissipation: Dual-fan air cooling design, fan speed 4500 RPM, noise level 75 dB (measured at 1 meter). When the ambient temperature exceeds 35℃, the hash rate decreases by 3-5%
1.2 Advanced Version Antminer L11 Pro
- Core Upgraded Parameters:
- Hash Rate: Rated 21 GH/s, actual measured hash rate ranges from 20.1-20.8 GH/s (±2.3% fluctuation), achieving a 5.8% hash rate increase through chip frequency optimization
- Power Consumption: 3480-3650W, 2.0-1.9% lower than the standard version. The power efficiency ratio is optimized to 172-178 J/GH, outperforming the competing DG2+ (179 J/GH) and the previous-generation L9 (210 J/GH)
- Heat Dissipation: Optimized air duct design, 12% increase in air volume. The core temperature is 4-6℃ lower than the standard version, and hash rate stability is improved by 8% under the same environmental conditions
- Physical Specifications: Consistent with the standard version, net weight increased to 15.2kg, compatible with existing Antminer L11 series mounting brackets
1.3 Flagship Water-Cooled Version Antminer L11 Hyd 6U
- Exclusive 6U Rack Design Parameters:
- Dimensions: 880×482×267mm (6U rack unit, 1U = 44.45mm), supporting high-density mining farm stacking deployment
- Weight: 32.8kg (including water-cooling module), requiring a dedicated load-bearing rack (load capacity ≥50kg/unit)
- Interfaces: Added water-cooling pipeline interface (G1/4 thread), supporting connection to centralized water-cooling systems in mining farms
- Peak Performance Parameters:
- Hash Rate: Rated 33 GH/s, actual measured peak hash rate ranges from 31.5-32.3 GH/s (±1.5% fluctuation) in 48-hour stress tests, 1.68 times that of the standard version
- Power Consumption: 5500-5800W, power efficiency ratio as low as 172-179 J/GH. At 30℃ ambient temperature, the core temperature is stably controlled below 65℃, 18-22℃ lower than air-cooled models
- Heat Dissipation System: Hybrid design of water-cooled main control (custom heat sink fins + high-efficiency water pump, flow rate 1.2L/min) + air-cooling auxiliary (4 sets of quiet fans, speed 3800 RPM), reducing noise level to 60 dB
II. Deployment Recommendations and Limitations
2.1 Optimal Use Cases
Medium-Large Mining Farms: The L11 Pro’s balance of performance and cost makes it ideal for batch deployment (100+ units). At
0.05/kWh, The payback period is reduced to 12 months.
Low-Electricity-Cost Regions: Recommended for areas with electricity rates ≤$0.08/kWh. Above this threshold, the higher power consumption (vs. DG2+) may erode profitability.
2.2 Operational Limitations
Noise Restrictions: 75 dB noise levels require industrial-grade sound insulation or outdoor deployment. Residential use is strongly discouraged.
Cooling Dependencies: In high-humidity environments (>80%), monthly maintenance of fan filters is necessary to prevent dust accumulation and overheating.
CONCLUSION
The Bitmain Antminer L11 Series stands as a testament to the ongoing evolution of Scrypt mining technology, delivering iterative advancements that cater to diverse miner needs—from enhanced hashing power and class-leading energy efficiency (as low as 172 J/GH) to adaptive cooling solutions tailored for every scale. Whether selecting the entry-level L11, the efficiency-focused L11 Pro, or the high-density L11 Hyd 6U, each model delivers consistent, industry-leading performance specifically optimized for Dogecoin (DOGE) and Litecoin (LTC) mining—two of the most widely mined Scrypt-based cryptocurrencies.
For small-scale operators, home miners, or those new to Scrypt mining, the air-cooled Standard L11 and L11 Pro shine: they require minimal setup (compatible with 19-inch standard racks) and low maintenance (weekly fan filter checks), while still delivering reliable hashrates (18.5–19.2 GH/s for the Standard, 20.1–20.8 GH/s for the Pro) and efficiency that outperforms legacy models like the Antminer L9. In contrast, the L11 Hyd 6U redefines large-scale mining potential: its 6U rack design, 31.5–32.3 GH/s peak hashrate, and ultra-low 60 dB noise level (vs. 75 dB for air-cooled models) make it a standout for dense, noise-sensitive data center deployments—cutting space costs by 44% compared to air-cooled clusters of the same Computing power.
Beyond raw performance, the L11 Series’ longevity is anchored in thoughtful engineering: refined PSU compatibility (supporting 220–277V single-phase input for flexibility), feature-rich firmware (including OTA updates and dual-mode performance tuning), and robust environmental adaptability (operating reliably at 5–45°C). These attributes ensure consistent output even under demanding conditions—critical as Scrypt network difficulty continues to rise .
Solo Miner
Bitcoin
Dogecoin
Aleo
Kaspa
ALPH
Nexa
ETC
CKB
Dash
Kadena