20-Slot 200kW Whatsminer 2U Modular Hydro Cooling Rack

A 20-slot 200kW hydro cooling cabinet designed for WhatsMiner hydro miners. Its split-type architecture enables flexible deployment with customized CDU and heat dissipation equipment for different mining sites.

    💬

    Customize Your Hydro Cooling Solution

    Share your requirements below. Our consultant will contact you via email, WhatsApp, or call within 24 hours with a custom setup and quote.

    Price range: $11,820.00 through $12,800.00

    Not Fitting Your Site?

    Tell us your mining capacity and site requirements, and we'll recommend the right hydro-cooling container for your deployment.

      💬

      Customize Your Hydro Cooling Solution

      Share your requirements below. Our consultant will contact you via email, WhatsApp, or call within 24 hours with a custom setup and quote.

      How your container order works

      1

      Submit form

      Tell us delivery country & site details

      2

      Get your quote

      Complete pricing within 24 hours

      3

      Expert review

      Discuss specs, customise setup

      4

      DDP delivery

      Container shipped to your site

      Flexible 200kW hydro cooling hub for 20 WhatsMiner units

      CONTAINER CAPACITY

      ASIC MINERS

      20 UNITS

      Housed at full load

      TOTAL POWER

      200 KW

      Continuous electrical load

      FORM FACTOR

      Custom

      Standard

      COOLING

      Hydro

      Thermal management

      POWER INPUT

      380V–415V AC 50/60Hz

      AVAILABILITY

      Typical lead time 15 days • DDP Sea Shipping Available

      Product Description

      Designed for efficient and flexible ASIC mining deployment, this 20-slot split-type hydro cooling cabinet supports up to 200kW of cooling capacity for WhatsMiner hydro miners.

      Its separated cabinet and heat dissipation design allows the cooling equipment to be positioned according to actual site conditions, making installation easier across different mining environments. The system can be paired with a customized CDU and heat rejection equipment based on the required cooling load, miner configuration, and deployment space.

      With a practical modular structure, it provides a reliable starting point for hydro-cooled mining operations while leaving room for future system adjustments and expansion.

      Core Advantages

      DCX HYDRO Crypto Mining Systems

      01. Integrated All-in-One Design

      The rack, CDU, power cabinet, and controller are all built into one single cabinet. Once delivered, simply connect the water pipes and power cables to start running—no complex assembly required.

      liquid cooling for Blockchain

      02. Leak-Proof Valve System

      High-seal manifolds and reinforced pipes prevent coolant leaks at the source. Red and blue valves control hot and cold water; simply turn them off to isolate lines during maintenance with zero spills.

      Hydro Cooling System for Whatsminer HYD Series

      03. PDU Individual Breakers

      The PDU power panel features a 1-to-1 breaker design, giving every single miner its own dedicated switch. If one unit needs servicing, just trip its specific breaker without affecting the rest of the rack.

      2.4MW 240-Slot Avalon / Sealminer 2U Bitcoin Mining Hydro-Cooling Container – Leak Detection

      04. Bottom Water Leak Detection

      A water-sensing rope is installed along the bottom edge of the cabinet. If coolant leaks to the floor, it triggers an instant alarm so onsite staff can fix it before any miners get damaged.

      Whatsminer miner Hydro Cooling System

      05. Durable Fittings & Solid Build

      Features 304 stainless steel manifolds, industry-standard aviation plugs, and reinforced high-pressure tubing with manual ball valves. Solidly sealed and durable for long-term use.

      28-Slot 154kW Antminer liquid cooling Cabinet CDU

      06. Customizable & Expandable CDU

      The CDU shown is fully customizable and expandable. We can adjust its cooling capacity, pump specs, and expansion ports based on your specific site conditions, miner count, and heat rejection equipment.

      Modular 1-to-N Infrastructure Scalability

      The 1-to-N modular design enables flexible power expansion from 200kW up to 1,000kW, allowing mining sites to scale based on evolving demand. Featuring a customized high-flow pump system and a dedicated power control cabinet, this solution ensures reliable management across multiple racks—eliminating the need for major infrastructure overhauls as your hashrate grows.

      Hydro cooling system for Whatsminer

      Full Specifications

      External dimensions

      L:850mm、W:1000mm、H:2130mm

      Internal dimensions

      L:800mm、W:950mm、H:2080mm

      Weight

      230KG

      Model

      AP-EM20

      Installed capacity

      20 Seat

      Installed powerload

      200 kW

      Power of the light-duty vertical multistage pump

      4 kW

      Power of the fluid replenishing pump

      0.2 kW

      Total power of the dry cooling tower fan

      8.3 kW

      Total power of the closed cooling tower fan

      3 kW

      Total power of the closed cooling tower spray pump

      1.1 kW

      System pipeline pressure

      0.2-0.4 MPA

      Operating temperature range of the system

      0-50 ℃

      Coolant circulation demand of a single machine

      ≥0.6 m³/h

      Total demand for circulating coolant within the system

      ≥0.25 m³

      Residual Current Circuit Breaker

      400 A

      Contactor

      9 A

      Intermediate relay

      24 V

      CUL certified frequency converter

      380 V

      Plug & Play with cooling system

      20-Slot Whatsminer Modular Hydro Cooling Rack Product Brochure

      Complete product specifications, installation guide, and operational instructions.

        Data download verification

        Downloadable materials: 20-Slot 200kW Whatsminer 2U Modular Hydro Cooling Rack

        Certification Standards

        Our products meet leading international standards for safety, reliability, and performance.

        China Classification Society

        Marine & offshore compliance

        UL Listed

        Safety tested & certified

        CSA Certified

        North American compliance

        CE Marking

        European conformity

        Complete Cooling Solutions

        We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

        ❄️ Cooling Capacity

        ⚙️ Miner Slots 

        📏 Dimensions (L × W × H)

        🏢 Application

        Whatminer Liquid Cooling Rack

        12-Slot Whatsminer Integrated Hydro Cooling Rack

        120 kW

        12 Slots

        8,50 × 1,000 × 2,130 mm

        Professional Home Setups

        Compare

        Whatminer Liquid Cooling Rack

        20-Slot Whatsminer Modular Hydro Cooling Rack

        200 kW

        20 Slots

        8,50 × 1,000 × 2,130 mm

        Modular Facility Scaling

        WhatsMiner hydro cooling system

        160-Slot Whatsminer Hydro Cooling Container

        1.6 MW

        160 Slots

        6,058 × 2,438 × 2,896 mm

        Industrial Mining Projects

        Whatminer 2.4MW 240 Slot hydro cooling container

        240-Slot Whatsminer Hydro Cooling Container

        2.4 MW

        240 Slots

        1,3716 × 2,438 × 2,896 mm

        Mega-Scale Global Farms

        Real Results from Real Miners

        View All  >>

        Hydro Cooling System for ASIC Bitcoin Mining
        Muscat, Oman

        2 x 1-to-1 Standalone Setups

        Operating two independent 1-to-1 systems with dedicated dry coolers to ensure maximum redundancy for 2U hydro miners in a high-heat environment.

        100%

        System Redundancy

        +28%

        Thermal Stability

        120W USD

        Independent Cluster

        View All >>

        2MW 200-Slot Whatsminer Hydro Mining Rack Deployment Case Study
        Southeast Asia

        1-to-5 High-Density Expansion

        Utilizing one centralized high-flow CDU and a standalone power cabinet to drive five 20-slot racks, supporting a 100-unit Whatsminer 2U cluster.

        +30%

        Space Efficiency

        -28%

        Setup TimeSetup Time

        1.1MW

        Total Capacity

        View All >>

        Global Deployment

        1.2+ GW

        Cumulative delivered cooling capacity

        Serving Mining Sites

        50+

        Countries and regions covered

        20-Slot Whatsminer 2U Modular Hydro Cooling Rack FAQs

        Can a 200kW cooling rack run 20 WhatsMiner Hydro miners?

        Yes, provided the combined miner load remains within the system's 200kW capacity.

        The rack provides 20 individual miner positions and is designed for compatible WhatsMiner M53, M63, and M73 series Hydro miners. Actual total power should always be calculated according to the exact miner model and operating mode before deployment.

        Does this cooling rack support overclocked WhatsMiner Hydro miners?

        Yes. The system is designed to support high-power and overclocked WhatsMiner Hydro mining deployments.

        With up to 200kW of miner load capacity, it provides sufficient cooling and circulation capacity for high-performance operation. The actual number of miners and overclocking level should be configured according to the combined power consumption of the installed miners to keep the total load within the system's rated capacity.

        Can different WhatsMiner Hydro models be installed in the same rack?

        Compatible M53, M63, and M73 series miners can be deployed in the same rack, provided their physical dimensions, electrical requirements, cooling connections, and total power load are compatible with the system.

        The exact miner combination should be confirmed before installation, especially when mixing different generations or power levels.

        How does the system keep sufficient coolant flow across 20 miners?

        The rack uses a centralized circulation system with automatic pressure regulation and constant-flow PLC control.

        The system has a rated circulation flow of 13m³/h, while each miner branch requires sufficient individual coolant flow. Correct flow distribution is important because adequate total system flow does not automatically guarantee equal flow through every miner.

        Are the quick connectors included with the cooling rack?

        Yes. The required quick connectors are prepared and installed before shipment according to the compatible WhatsMiner Hydro miners.

        During installation, the miner's cooling inlet and outlet can be connected directly to the corresponding supply and return lines on the rack, reducing on-site piping work and simplifying deployment.

        Can individual miners be managed without controlling the entire rack?

        Yes. Each miner position is designed with individual control, while the complete cooling rack is centrally managed through a PLC system.

        The PLC monitors key operating conditions such as power, coolant temperature, flow, pressure, and network status. MODBUS-RTU communication is also supported for integration with site-level monitoring and control systems.

        What electrical infrastructure is required for a fully loaded 20-miner rack?

        A 20-miner Hydro deployment requires industrial three-phase electrical infrastructure sized for the actual miner load plus the cooling and control equipment.

        The system should not be sized only around the miners' nominal power. Pumps, control equipment, external heat-rejection equipment, circuit protection, cables, and any planned high-performance or overclocking modes should also be included in the electrical design.

        Can multiple 200kW racks be added as the mining farm expands?

        Yes. The rack-based design is suitable for modular expansion.

        A site can start with one 20-miner rack and add additional racks as power and cooling capacity become available. For larger deployments, the total electrical capacity, coolant distribution, pumping system, heat-rejection capacity, piping layout, and centralized monitoring should be planned at the site level rather than treating each rack independently.