Bitmain ANTRACK V2 24kW For 4 Units Hydro Cooling Solution

Bitmain ANTRACK V2 is a 24kW split-type hydro cooling cabinet supporting up to 4 hydro miners. Plug-and-play design with versatile heating support.

    💬

    Customize Your Hydro Cooling Solution

    Share your requirements below. Our consultant will contact you via email, WhatsApp, or call within 24 hours with a custom setup and quote.

    Immediate4–8 weeks8–12 weeks12+ weeks

    $8,888.00

    Not Fitting Your Site?

    Tell us your mining capacity and site requirements, and we'll recommend the right hydro-cooling container for your deployment.

      💬

      Customize Your Hydro Cooling Solution

      Share your requirements below. Our consultant will contact you via email, WhatsApp, or call within 24 hours with a custom setup and quote.

      How your container order works

      1

      Submit form

      Tell us delivery country & site details

      2

      Get your quote

      Complete pricing within 24 hours

      3

      Expert review

      Discuss specs, customise setup

      4

      DDP delivery

      Container shipped to your site

      Modular 24kW hydro cooling hub with 80°C heat recovery for Antminer units

      CONTAINER CAPACITY

      ASIC MINERS

      4 UNITS

      Housed at full load

      TOTAL POWER

      24 KW

      Continuous electrical load

      FORM FACTOR

      Custom

      Standard

      COOLING

      Hydro

      Thermal management

      POWER INPUT

      380V–415V AC 50/60Hz

      AVAILABILITY

      In stock, ready to ship • DDP Sea Shipping Available

      24 kW Heat Recovery Solution

      Turn Mining Waste Into Sustainable Energy

      Repurpose your miner’s thermal output to support space heating or domestic hot water. The ANTRACK V2 recovers heat to provide up to 80°C warmth, effectively lowering your utility bills while you generate Bitcoin.

      PROMOTIONAL BUNDLE OFFER

      1 × ANTRACK V2 + 4 × ANTMINER

      Save thousands with our special package price. Buy the full system together to lower your upfront costs and speed up your ROI.

      24kW

      Total Power

      1,172TH/s

      Example Hashrate

      ≈ 0.212 BTC

      Estimated Annual Revenue

      REVENUE AT A GLANCE

      How much revenue can your surplus electricity generate in a year?

      BTC Reference Price

      ≈ $62,767

      Estimated Annual Revenue

      ≈ $13,335

      Indicative Payback Period 5.6 months

      Historical BTC High

      ≈ $126,211

      Estimated Annual Revenue

      ≈ $26,813

      Indicative Payback Period 2.8 months

      BTC Price Scenario

      $200,000

      Estimated Annual Revenue

      ≈ $42,490

      Indicative Payback Period 1.8 months

      "Revenue estimates assume 24kW surplus power, 1,172 TH/s, year-round operation and current network conditions.
      Payback is based on the S6,20d package price. Mining pool fees, O&M and installation costs are excluded.
      Actual results vary with BTC price, network ditticulty and operating time. All amounts are in USD.

      WHERE DOES YOUR SURPLUS POWER COME FROM?

      If your site can rellably provide around 24kW of surplus power, further assessment is worthwhile.

      01. Small Hydropower

      Is wet-season power curtalledor sold at very low prices?

      02. Solar /Wind

      Do peak output or grid limits leave power unused?

      03. Biogas /Biomass

      Does continuous generation exceed on-site demand?

      04. Industrial / On-Site Power

      Is stable power left unusedwhen production loads fall?

      Full Specifications

      Without package

      L:1200mm、W:600mm、H:1300mm

      With package

      L:1460mm、W:780mm、H:1330mm

      Weight

      210KG

      Model

      ANTRACK V2-EC4-DTHP

      Installed capacity

      4 units ANTMINER (Hydro) or 4 units ANTMINER (U2 Hydro) or 2 units ANTMINER (U3 Hydro) 

      Heat Dissipation Capacity

      24 kW

      Power supply AC Input voltage

      380~415V AC

      Power supply AC Input Frequency Range

      60 Hz

      Power supply AC Input current

      63 Amp

      Rated power

      450 W

      Noise

      60 dBA@1m

      Lift

      19 M

      Diameter of water pipe connector

      DN20 MM

      External Cooler

      Size (L*W*H), (without package)

      1340*570*1330 MM

      Size (L*W*H), (with package)

      1490*590*1495 MM

      Net weight,  (without package)

      235 KG

      Gross weight,  (with package)

      248 KG

      Power supply AC input voltage

      380~415V AC

      Power supply AC input frequency range

      50~60 Hz

      Maximum power supply AC input current

      21 Amp

      Heating Capacity (typical)

      32 KW

      Compressor Input (typical)

      8 KW

      EER (typical)

      3.0

      Sound Level

      50 Db(A)

      Refrigerant

      R290

      Heating water outlet temperature

      80 °C

      4-Slotr Antminer Hydro Cooling Rack Product Brochure

      Complete product specifications, installation guide, and operational instructions.

        Data download verification

        Downloadable materials: Bitmain ANTRACK V2 24kW For 4 Units Hydro Cooling Solution

        Real-World Hydronic Heating Solutions

        Discover how our ANTRACK V2 24kW Hydro Cooling System bridges high-performance computing with sustainable heating—turning server heat and surplus power into reliable, low-cost warmth for communities and commercial buildings.

        Key Highlights & Proven Results

        • Delivers 54°C–80°C hot water to building heating loops in Martinville, Canada, projected to cut community heating bills by nearly 50%.
        • Converts unused clean power at a UK hydro station into productive computing capacity, monetizing surplus renewable energy without waste.
        • Seamlessly connects to existing radiators, underfloor heating, and hot water networks, with flexible heat reuse for greenhouses and pools.

        Complete Cooling Solutions

        We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

        ❄️ Cooling Capacity

        ⚙️ Miner Slots 

        📏 Dimensions (L × W × H)

        🏢 Application

        Compare

        ANTRACK V2

        4-Slot Antminer Hydro Cooling Rack

        24 kW

        4 Slots

        1,200 × 6,00 × 1,300 mm

        Home Setup & Heat Recycling

        AP-H6 liquid cooling system

        6-Slot Antminer Hydro Cooling Rack

        35 kW

        6 Slots

        8,00 × 8,00 × 1,450 mm

        Standard Workshop Mining

        AP-H9 liquid cooling system

        9-Slot Antminer Hydro Cooling Rack

        50 kW

        9 Slots

        8,00 × 8,00 × 1,600 mm

        Professional Home Facilities

        AP-H12 Liquid Cooling Rack

        12-Slot Antminer Hydro Cooling Rack

        70 kW

        12 Slots

        7,00 × 8,00 × 1,800 mm

        High-Capacity Residential Mining

        Real Results from Real Miners

        View All  >>

        ANTRACK V2 Hydro Mining Deployment Case Study
        Zurich, Switzerland

        4 x 24kW Small Facility Project

        Scaling a workshop operation by mixing standard Antminer hydro units and 3U server-grade miners in a single cluster.

        +100%

        Heat Reuse

        -42dB

        Noise Reduction

        $0

        Extra Heating Fuel

        View All >>

        4 Slot Antminer Hydro Mining Container Deployment Case Study
        Salt Lake City, United States

        2 x 24kW Home Heating Project

        Integrating two ANTRACK V2 units into a residential attic to support an entire floor's underfloor heating system.

        -28%

        Payback Period

        -35%

        Energy Expenses

        99.9%

        Thermal Stability

        View All >>

        Global Deployment

        1.2+ GW

        Cumulative delivered cooling capacity

        Serving Mining Sites

        50+

        Countries and regions covered

        4-Slot Antminer Hydro Cooling Rack FAQs

        Which miner models are compatible with the ANTRACK V2 24kW?

        The ANTRACK V2 features a 2-tier rack that supports up to a 24kW thermal load with flexible configurations:

        • Up to 4 units: Classic Antminer Hydro miners (e.g., S19 Hydro series, S21 XP Hydro) or standard 2U miners (2 units per tier).

        • Up to 2 units: Standard 3U / RACK483 water-cooled server miners (1 unit per tier).

        • Mix-and-Match: You can freely combine different models (e.g., one 3U miner on the top level and two 2U/Hydro miners on the bottom level).

        How do the dual operation modes (Cooling vs. Heat Recovery) work?

        The system operates in two intelligent modes depending on your seasonal needs:

        • Heat Dissipation Mode: Hot water from the miners is routed through the dry cooler and high-efficiency fan to exhaust excess heat directly, maintaining a stable ~35°C cooling loop year-round.

        • Heat Recovery Mode: Thermal energy is captured by the heat pump's evaporator and transferred to the condenser, elevating the water temperature to 50°C–80°C for active space heating or hot water supply.


        What water temperatures can the system deliver, and how much area can it heat?
        • Miner Side: Continuous and stable cooling water supply at ~35°C, ensuring optimal hash rate and hardware longevity.

        • Heating Side: Supplies usable hot water from 50°C up to 80°C.

        • Heating Coverage: Paired with high-efficiency miners like the S21 XP Hydro, a single ANTRACK V2 can heat up to 640 m² (based on a standard heating load of 50 W/m²).

        Where can the recovered heat be applied?

        The heat pump unit comes with dedicated external supply pipelines that seamlessly connect into:

        • Building & Space Heating: Radiator loops and hydronic underfloor heating for residential homes, offices, or hotels.

        • Hot Water Systems: Domestic hot water (DHW) pre-heating.

        • Agriculture & Leisure: Commercial greenhouses, indoor farming, and swimming pool / hot tub heating.

        • Light Industrial: Any low-to-medium temperature industrial process requiring reliable hot water.


        How is the system installed and connected to existing heating loops?

        The ANTRACK V2 features a plug-and-play split design:

        1. Cabinet & Heat Pump Loop: Connect the cooling cabinet's internal pump/heat exchanger to the heat pump unit using the pre-configured quick-connect ports.

        2. Heating Loop: Connect the secondary pipeline ports on the heat pump directly into your facility's hydronic heating network.

        3. Fill with coolant, power on the control switches, and the system automatically manages water circulation and heat transfer.

        How does heat recovery shorten the ROI (Payback Period)?

        ANTRACK V2 creates a dual-revenue stream: Bitcoin mining rewards + substantial savings on heating/gas bills. For example, when running S21 XP Hydro units at an electricity cost of $0.08/kWh and offsetting local heating costs, the estimated payback period can be as short as ~465 days.