20-Slot 200kW Antminer 2U Hydro Cooling System

Deploy our 20-slot, 200kW liquid cooling system for Antminer 2U liquid-cooled miners. The system features a 42U indoor cabinet, an integrated CDU, a PUE of <1.05, and an outdoor dry cooler.

    Immediate4–8 weeks8–12 weeks12+ weeks

    Not Fitting Your Site?

    Tell us your mining capacity and site requirements, and we'll recommend the right hydro-cooling container for your deployment.

      💬

      Customize Your Hydro Cooling Solution

      Share your requirements below. Our consultant will contact you via email, WhatsApp, or call within 24 hours with a custom setup and quote.

      How your container order works

      1

      Submit form

      Tell us delivery country & site details

      2

      Get your quote

      Complete pricing within 24 hours

      3

      Expert review

      Discuss specs, customise setup

      4

      DDP delivery

      Container shipped to your site

      20-Slot 200kW Hydro Cooling System for Antminer 2U

      CONTAINER CAPACITY

      ASIC MINERS

      20 UNITS

      Housed at full load

      TOTAL POWER

      200 KW

      Continuous electrical load

      FORM FACTOR

      Custom

      Standard

      COOLING

      Hydro

      Thermal management

      POWER INPUT

      380V–415V AC 50/60Hz

      AVAILABILITY

      In stock, ready to ship • DDP Sea Shipping Available

      Product Description

      The 20-Slot 200kW Hydro Cooling System is a specialized liquid cooling solution engineered specifically for Antminer 2U models. As dedicated 2U hydro infrastructure remains rare across the market, this standardized 42U rack delivers a purpose-built solution—housing up to 20 units of Antminer S23e U2H, L9 Hyd 2U, and L11 Hyd 2U with an ultra-low PUE below 1.05.

      Pairing an indoor hydro cabinet with a high-efficiency outdoor dry cooler, the system guarantees stable thermal performance across demanding climates. The integrated CDU automatically balances fluid circulation, keeping chip temperatures optimal to eliminate heat-induced throttling and ensure full-hashrate stability.

      Factory pre-wired and pre-plumbed for true plug-and-play commissioning, the system minimizes on-site deployment time. It also supports flexible custom configurations and modular multi-rack expansion, allowing operators to seamlessly scale their 2U hydro capacity as their mining operations grow.

      Core Advantages

      Modular 1-to-N Infrastructure Scalability

      The 1-to-N modular design enables flexible power expansion from 200kW up to 1,000kW, allowing mining sites to scale based on evolving demand. Featuring a customized high-flow pump system and a dedicated power control cabinet, this solution ensures reliable management across multiple racks—eliminating the need for major infrastructure overhauls as your hashrate grows.

      Centers Modular liquid cooling solutions

      Full Specifications

      External dimensions

      L:950mm、W:600mm、H:2150mm

      Internal dimensions

      L:950mm、W:600mm、H:2150mm

      Weight

      250KG

      Model

      AP-A2U20

      Installed capacity

      20 Seat

      Certification 

      UL/CE certification

      System composition

      Dry cooler *1
      Cabinet*1+CDU&PLC+External Piping

      System energy consumption

      10 kW

      Heat dissipation capacity

      >200KW

      Environmental adaptability 

      -20℃~45℃
      Standard con

      Cabinet specifications 

      42U Standard Cabinet

      Constant temperature mode

      Variable frequency speed control of EC fan+EC fan stepwise regulation

      Pump

      3kW*1

      Cabinet weight

      250kg

      Cabinet Dimensions 

      950mm(L)*600mm(W)*2150mm(H)

      CDU weight

      250kg

      CDU Dimensions 

      1050mm(L)*600mm(W)*2150mm(H)

      Dry cooler weight

      650kg

      Dry cooler Dimensions

      2400mm(L)*1450mm(W)*1730mm(H)

      Plug & Play with cooling system

      20-Slot Antminer 2U Hydro Cooling Rack Product Brochure

      Complete product specifications, installation guide, and operational instructions.

        Data download verification

        Downloadable materials: 20-Slot 200kW Antminer 2U Hydro Cooling System

        Certification Standards

        Our products meet leading international standards for safety, reliability, and performance.

        China Classification Society

        Marine & offshore compliance

        UL Listed

        Safety tested & certified

        CSA Certified

        North American compliance

        CE Marking

        European conformity

        Complete Cooling Solutions

        We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

        ❄️ Cooling Capacity

        ⚙️ Miner Slots 

        📏 Dimensions (L × W × H)

        🏢 Application

        Compare

        20-Slot 200kW Antminer 2U Hydro Rack for Bitcoin Mining

        20-Slot Antminer 2U Hydro Cooling Rack

        200 kW

        20 Slots

        950 × 600 × 2150 mm

        Modular Facility Expansion

        ANTRACK AR31 200kW

        ANTRACK AR31 20-Slot Antminer 2U Hydro Cooling Rack

        200 kW

        20 Slots

        1,000 × 12,00 × 2,300 mm

        Home Setup & Heat Recycling

        ANTRACK AR30 200kW

        ANTRACK AR30 20-Slot Antminer 2U Hydro Cooling Rack

        200 kW

        20 Slots

        1,000 × 12,00 × 2,300 mm

        Professional Home Facilities

        15-Slot Antminer Hydro Cooling Rack

        15-Slot Antminer 3U Hydro Cooling Rack

        200 kW

        15 Slots

        8,00 × 1,050 × 2,100 mm

        Modular Facility Expansion

        20-Slot Antminer 2U Hydro Cooling Rack FAQs

        Which miners are compatible with this 20-slot hydro cooling rack?

        The system is purpose-built and factory-matched for the Antminer 2U hydro series, providing 20 standardized slots engineered specifically for models including the Antminer S23e Hyd 2U, L9 Hyd 2U, and L11 Hyd 2U. The 42U cabinet's internal mounting rails, quick-connect water manifolds, and dedicated 20A circuit breakers are precision-configured to match the exact chassis dimensions, power inputs, and thermal dissipation requirements of these 2U units out of the box.

        Does the outdoor dry cooler consume water, and how do the wet curtains work?

        Under standard ambient temperatures, the system operates as a closed-loop dry cooler with zero water consumption, circulating coolant without evaporative loss. The integrated adiabatic wet curtains serve as an optional high-temperature booster. During peak summer heat waves (when ambient air exceeds 35°C–40°C), wetting the curtains pre-cools the incoming air through evaporation, maintaining high heat transfer efficiency and preventing miner thermal throttling with minimal water usage.

        What are the electrical supply and transformer requirements for this system?

        The system requires a 380V–415V AC 3-phase power supply (50/60Hz). Total power consumption is approximately 210 kW (covering 20 high-power 2U miners plus the cooling pumps and dry cooler fans). The indoor rack comes pre-wired with an integrated industrial PDU featuring twenty 20A circuit breakers (20A × 20) for individual slot protection. Operators typically require a dedicated 250 kVA to 315 kVA transformer (or equivalent facility headroom) to support continuous full-load operation.

        How are the indoor 42U cabinet and outdoor dry cooler connected? What is the maximum piping distance?

        The indoor rack connects to the outdoor dry cooler via two insulated fluid pipes (supply and return) powered by the CDU’s integrated 17.3 m³/h circulation pump. The standard recommended piping distance between the indoor cabinet and outdoor cooler is within 10 to 15 meters (30–50 ft) using DN50/DN65 pipes to ensure minimal pressure drop and optimal flow rates. If your site requires longer pipe runs, our engineering team can provide auxiliary booster pump guidance.

        Can multiple 20-slot racks be scaled or linked together for larger warehouse deployments?

        Yes, the system is fully modular and scalable. Operators can deploy individual stand-alone units (1 rack + 1 dry cooler) or parallel multiple 42U racks together in warehouse environments. For multi-rack deployments, multiple indoor cabinets can either retain dedicated dry coolers for independent redundancy or tie into a centralized high-capacity outdoor cooling loop, allowing your 2U hydro fleet to expand smoothly from 20 units to hundreds of units.

        What safety protections and alarms are integrated into the CDU?

        The all-in-one CDU is equipped with an automated PLC control module that monitors key hydraulic parameters in real time. It features a low-liquid-level alarm to detect coolant loss, an automated blowdown/drainage alarm for maintenance, and loop pressure/temperature tracking. If an abnormal pressure drop or critical fluid temperature is detected, the system triggers alerts to protect ASIC hashboards and electrical components from thermal and dry-run damage.