This 20ft hydro mining container supports 160 Whatsminer or Avalon 2U hydro rigs, also compatible with 104 Antminer 3U rigs for efficient hydro cooling, delivering 1.6MW capacity.
160-Slot High-Density Hydro Cooling Container for Whatsminer 2U Series
CONTAINER CAPACITY
ASIC MINERS
160 UNITS
Housed at full load
TOTAL POWER
1,600 KW
Continuous electrical load
FORM FACTOR
Custom
Standard
COOLING
Hydro
Thermal management
POWER INPUT
380V–415V AC 50/60Hz
AVAILABILITY
Typical lead time 45 days • DDP Sea Shipping Available
View More ›

Whatsminer M53S++
➔
320Th/s · 22 J/Th
160 Slots
Full‑load: $1,952.00/day

Whatsminer M63S
➔
390Th/s · 18.5 J/Th
160 Slots
Full‑load: $2,379.20/day

WhatsMiner M73
➔
526 TH/s · 14.5 J/Th
160 Slots
Full‑load: $3,208.00/day

WhatsMiner M73S
➔
552 TH/s · 13.5 J/Th
160 Slots
Full‑load: $3,366.40/day

WhatsMiner M73S+
➔
600 TH/s · 12.5 J/Th
160 Slots
Full‑load: $3,659.20/day
Show 1 more models
Product Description
Optimized for high density configurations, the 1.6MW 160-Slot Whatsminer 2U Hydro Cooling Container 20FT HQ maximizes physical space utilization.
Built to pack 160 Whatsminer 2U hydro servers into the same compact 20 foot frame, this scalable infrastructure manages a heavy 1600kW thermal load. It utilizes engineered high flow stainless steel manifolds and robust CDU circulation to guarantee uniform water pressure across all highly compressed server rows under continuous full load operations.
Ideal for footprint constrained sites seeking maximum hashing output and capital return, this highly integrated, space saving water cooling container minimizes total onsite land overhead while securing highly consistent thermal cooling performance globally.
Core Advantages
01. Integrated All-in-One System
Integrates the server racks, CDU, power cabinet, and control unit into a single 20FT container for rapid on-site setup, minimizing civil engineering costs and deployment time.
02. Advanced CDU System
The CDU system manages critical heat exchange between the internal and external water loops, continuously regulating coolant flow, stabilizing loop pressure, and optimizing overall thermal efficiency.
03. Redundant Dual-Loop Cooling
Engineered with seamless, single-piece dual-loop piping to prevent leaks, utilizing red markers for hot water and blue for cold to ensure continuous operations during power limits.
04. Individual Power Switches
Every miner slot is equipped with an independent breaker, enabling safe, hot swappable maintenance on single units without disrupting any other operational units.
05. Instant Leak Detection
Uses high-sensitivity, floor-mounted moisture-sensing ropes to instantly detect any coolant leaks, triggering immediate remote alarms and automatic power cutoffs to protect your hardware.
06. Standard 2U Server Racking
Racks specifically designed for 2U miners are custom matched with Whatsminer's series, featuring smooth sliding rails and drawer style setups to ensure effortless manual maintenance.
Full Specifications
External dimensions
L:6058mm、W:2438mm、H:2896mm
Internal dimensions
L:5860mm、W:2348mm、H:2720mm
Weight
4500KG
|
Model |
AP-HC20-M160 |
Installed capacity |
160 Seat |
|
Installed powerload |
1600 KW |
Power of the light-duty vertical multistage pump |
30 kW |
|
Power of the fluid replenishing pump |
0.2 KW |
Total power of the dry cooling tower fan |
41.5 KW |
|
Total power of the closed cooling tower fan |
17.6 KW |
Total power of the closed cooling tower spray pump |
4 KW |
|
System pipeline pressure |
0.2-0.4 MPA |
Operating temperature range of the system |
0-50 ℃ |
|
Coolant circulation demand of a single machine |
≥0.6 m³/h |
Total demand for circulating coolant within the system |
≥1.7 m³ |
|
Molded Case Circuit Breaker |
125 A |
Residual Current Circuit Breaker |
400 A |
|
Contactor |
9 A |
Intermediate relay |
24 V |
|
CUL certified frequency converter |
380 V |
160-Slot Whatsminer Hydro Cooling Container Product Brochure
Complete product specifications, installation guide, and operational instructions.
Certification Standards
Our products meet leading international standards for safety, reliability, and performance.
China Classification Society
Marine & offshore compliance
UL Listed
Safety tested & certified
CSA Certified
North American compliance
CE Marking
European conformity
Recommended Power Setup
Match your container deployment with the appropriate transformer capacity.
For 1 x 1.6 MW Container
2000 kVA Three-Phase Pad-Mounted Transformer
Complete Cooling Solutions
We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.
|
❄️ Cooling Capacity |
|
⚙️ Miner Slots |
|
📏 Dimensions (L × W × H) |
|
🏢 Application |
100-Slot Whatsminer Hydro Container
|
1 MW |
|
100 Slots |
|
6,058 × 2,438 × 2,896 mm |
|
Entry-Level Mining Sites |
120-Slot Whatsminer Hydro Container
|
1.2 MW |
|
120 Slots |
|
6,058 × 2,438 × 2,896 mm |
|
Commercial-Scale Operations |
Compare
160-Slot Whatsminer Hydro Container
|
1.6 MW |
|
160 Slots |
|
6,058 × 2,438 × 2,896 mm |
|
Industrial-Scale Projects |
240-Slot Whatsminer Hydro Container
|
2.4 MW |
|
240 Slots |
|
1,3716 × 2,438 × 2,896 mm |
|
Mega-Scale Mining Facilities |
Real Results from Real Miners
View All >>
Ciudad del Este, Paraguay
7x 1.6MW Hydro Project
Sustaining highly stable, high-yield operations under humid tropical climates.
+32%
Space Optimization
-25%
Cooling Power Draw
$1.1M
Annual Savings
View All >>
Irkutsk, Russia
8 x 1.6MW Hydro Project
Maintaining highly consistent thermal dissipation across freezing winter seasons.
+100%
Operational Uptime
99.9%
System Reliability
120W USD
Energy Cost
View All >>
“
"Squeezing 1.6MW into a 20FT container gave us substantial space savings. The pre-wired setup allowed our Siberian team to go online quickly, ensuring highly reliable, consistent winter hashing."
— O&M Director, Irkutsk Mining Facility, Russia
Operating 160 Whatsminer servers in Paraguay’s humid climate was our main concern. This container’s engineered manifolds maintain extremely balanced water pressure, keeping our chip temperatures completely stable."
— VP of Operations, Ciudad del Este Site, Paraguay
Global Deployment
1.2+ GW
Cumulative delivered cooling capacity
Serving Mining Sites
50+
Countries and regions covered
160-Slot Whatsminer Hydro Cooling Container FAQs
Which specific ASIC models are compatible with this 160-slot container?
This 1.62MW container is custom engineered for MicroBT standard 2U hydro servers, fully supporting the Whatsminer M53, M63, M73, M6d, and M7d series with exact matching internal cabinet rack dimensions.
How does the system prevent thermal hotspots under the high heat density of 160 packed miners?
To handle the intense 1600kW load in a 20FT container, we utilize customized large diameter water manifolds and robust CDUs, guaranteeing uniform water pressure and balanced coolant flow across all slots.
What are the concrete requirements for site level grid and transformer integration for this 1.6MW load?
Engineered for heavy duty industrial electricity grids, this container connects seamlessly to a standard 2000kVA transformer, simplifying site level power distribution and lowering your total onsite project CapEx.
What is the anti-corrosion coating process and the heat-insulating capability of the container shell?
The shell utilizes a three coat painting process to enhance overall corrosion resistance, while the internal structure is lined with foil faced fireproof insulation cotton, improving thermal stability under high temperatures.
Will pump failures, sensor malfunctions, or environmental anomalies instantly alarm and be located in the backend system?
Yes. The backend integrates smart warning systems, triggering instant alarms during any equipment anomalies. This covers water pumps, sensor arrays, and fans, helping onsite operators quickly locate exact fault positions.
Solo Miner
Bitcoin
Dogecoin
Aleo
Kaspa
ALPH
Nexa
ETC
CKB
Dash
Kadena